PRODUCTS
You are here: Home » Products » RO Water Treatment Equipment » Reverse Osmosis Water Purification System 500L

Reverse Osmosis Water Purification System 500L

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Wejing has extensive experience in manufacturing water purification systems for industrial applications. Our Reverse Osmosis Water Purification System 500L features:

  • 500L capacity for industrial water production
  • Primary and secondary water treatment systems
  • Filters up to 500 liters, removing impurities and contaminants
  • Uses reverse osmosis technology for superior water quality
  • Guarantees pure, safe water for industrial needs
  • Reliable and efficient treatment process

Send us your inquiry now, and we'll support your industrial water purification needs with our high-quality, eco-friendly Reverse Osmosis Water Purification System 500L.

Availability:
Quantity:
  • WJ-ROA500

  • Wejing



Product Advantage:

1. High Efficiency: Our system utilizes advanced reverse osmosis technology, ensuring efficient removal of impurities, contaminants, and harmful substances from water.

2. Enhanced Water Quality: With its primary and secondary water treatment systems, our system guarantees superior water quality, meeting stringent industrial standards.

3. Cost-effective Solution: By providing reliable and long-lasting filtration, our system helps reduce operational costs associated with water treatment and maintenance.

4. Easy Installation and Operation: Our system is designed for easy installation and user-friendly operation, minimizing downtime and maximizing productivity.

5. Sustainable and Environmentally Friendly: The reverse osmosis process consumes less energy compared to traditional water purification methods, contributing to a greener and more sustainable environment.


Technical Parameters:


model

Water yield T/H

Electric power

KW

Return power

%

Effluent conductivity US/CM

Number of membrane components

Raw water conductivity

WJ-ROA500

0.5

0.75

50

3-8

Two reverse osmosis membranes

<300


Product Uses:

1. Industrial Manufacturing: Purifies water for food production, pharmaceutical manufacturing, and electronics assembly. Ensures high-quality water for critical industrial processes.


2. Agriculture and Irrigation: Provides clean water for crop irrigation. Improves plant health and increases yield by removing harmful contaminants.


3. Laboratory and Research: Delivers ultra-pure water for scientific experiments. Meets stringent requirements of research facilities and medical laboratories.


4. Commercial Establishments: Supplies purified water for hotels, restaurants, and spas. Ensures safe water for drinking, cooking, and guest services.


5. Municipal Water Treatment: Removes impurities from community water supplies. Helps provide clean drinking water to residential areas and public facilities.


6. Healthcare Facilities: Purifies water for medical equipment sterilization and dialysis machines. Ensures patient safety in hospitals and clinics.


7. Beverage Industry: Produces clean water for soft drinks, beer, and bottled water. Maintains consistent product quality and taste.


8. Textile Manufacturing: Supplies purified water for dyeing and finishing processes. Improves color consistency and fabric quality.


9. Power Plants: Provides treated water for cooling systems and steam generation. Extends equipment lifespan and improves energy efficiency.


10. Aquaculture: Purifies water for fish farms and aquariums. Maintains optimal water conditions for aquatic life.

Reverse Osmosis Water Purification System 500L



Product Operate Guide:


1. Pre-Installation Check: Verify all components. Review installation instructions. Ensure proper tools are available. Check for damage during shipping.


2. System Connection: Connect to water source. Install plumbing fittings. Attach drain line. Connect storage tank. Follow guidelines for each connection.


3. System Start-up: Open water supply valve. Allow system to fill. Check for leaks. Flush system according to manual. Test water quality.


4. Regular Maintenance: Replace filters as scheduled. Clean membrane annually. Sanitize storage tank. Check and adjust system pressure. Monitor water quality.


5. Troubleshooting: Consult user manual for common issues. Check water pressure and flow. Inspect for leaks. Test water quality. Contact support if needed.


6. Water Quality Monitoring: Test output water regularly. Use provided test kit. Compare results to standards. Adjust system if necessary.


7. Filter Replacement: Turn off water supply. Release system pressure. Remove old filters. Install new filters. Sanitize system after replacement.


8. Membrane Cleaning: Prepare cleaning solution. Circulate through membrane. Rinse thoroughly. Test water quality after cleaning. Replace if performance declines.


9. System Winterization: Drain all water if freezing is possible. Disconnect power. Remove and store filters. Protect against frost damage.


10. Performance Optimization: Adjust pressure settings. Clean pre-filters regularly. Avoid extreme temperatures. Use system daily for best results.

FAQ:


Q: How often should I replace the filters in the system?

A: Filter replacement frequency depends on water quality and usage. Generally, it is recommended to replace pre-filters every 6-12 months and the RO membrane every 2-3 years.

Q: Can I use the system with well water?

A: Yes, the system can effectively treat well water. However, it is advisable to conduct a water analysis to determine any additional pre-treatment requirements.

Q: Is the system noisy during operation?

A: No, our system operates quietly. You may hear a slight sound during the water filling process, but it is minimal and should not cause any disturbance.

Q: Can the system remove fluoride from the water?

A: Yes, our reverse osmosis system is capable of removing fluoride along with other contaminants, ensuring clean and safe drinking water.

Q: What is the water wastage ratio of the system?

A: The water wastage ratio varies depending on factors such as water pressure and temperature. On average, our system achieves a 1:3 ratio, meaning for every gallon of purified water, three gallons are discharged as waste.

Previous: 
Next: 
CONTACT US INQUIRE NOW

We have always been committed to maximizing the "Wejing Intelligent" brand - pursuing champion quality and achieving harmonious and win-win results.

QUICK LINKS

PRODUCT CATEGORY

CONTACT INFORMATION

Add: 6-8 TIESHANHE Road, Huashan Town,Guangzhou City, China
Tel: +86-15089890309
Copyright © 2023 Guangzhou Wejing Intelligent Equipment Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy