Availability: | |
---|---|
Quantity: | |
WJ-RO
Wejing
Product Advantage:
1. High Capacity: Our system boasts a 5000L RO capacity, ensuring a continuous supply of purified water for industrial production needs.
2. Superior Water Quality: With reverse osmosis technology, our system effectively removes impurities, contaminants, and harmful substances, providing high-quality water for industrial applications.
3. Cost-effective Solution: By eliminating the need for expensive bottled water or alternative purification methods, our system offers a cost-effective solution for industrial water filtration.
4. Easy Maintenance: Our system is designed for easy maintenance, with accessible filters and user-friendly controls, minimizing downtime and maximizing productivity.
5. Reliable and Durable: Built with high-quality materials and advanced technology, our Water Filtration System Reverse Osmosis ensures long-lasting performance and reliability in industrial environments
model | Water yield | Electric power | Recovery | Primary effluent conductivity us/cm | Secondary effluent conductivity us/cm | EDI effluent conductivity us/cm | Raw water conductivity |
RO500 | 0.5 | 0.75 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO1000 | 1.0 | 2.2 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO2000 | 2.0 | 4.0 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO3000 | 3.0 | 5.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO5000 | 5.0 | 7.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO6000 | 6.0 | 7.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO10000 | 10.0 | 11 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO20000 | 20.0 | 15 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
1. Beverage Production: Our system provides purified water for beverage production, ensuring the highest quality and taste for soft drinks, juices, and bottled water.
2. Pharmaceutical Manufacturing: The system is ideal for pharmaceutical companies, delivering purified water that meets the stringent requirements of drug manufacturing processes.
3. Electronics Industry: Our system supplies ultra-pure water for electronics manufacturing, preventing contaminants that could damage sensitive components and ensuring product reliability.
4. Food Processing: The system is used in food processing plants to remove impurities and contaminants, ensuring safe and clean water for various production processes.
5. Power Generation: Our system is employed in power plants, providing purified water for boiler feedwater, cooling towers, and other critical applications, ensuring efficient and reliable power generation.
1. Pre-Installation Check: Verify all components. Review installation manual. Ensure tools are available. Check for shipping damage.
2. System Connection: Connect to water source. Install plumbing fittings. Attach drain line. Connect storage tank. Follow connection guidelines.
3. System Start-up: Open water supply valve. Allow system to fill. Check for leaks. Flush system. Test initial water output.
4. Regular Maintenance: Replace filters on schedule. Clean membrane annually. Sanitize storage tank. Check system pressure. Monitor water quality.
5. Troubleshooting: Consult manual for common issues. Check water pressure and flow. Inspect for leaks. Test water quality. Contact support if needed.
6. Water Quality Testing: Use provided test kit regularly. Compare results to standards. Adjust system if necessary. Document test results.
7. Filter Replacement: Turn off water supply. Release system pressure. Remove old filters. Install new filters. Sanitize system after replacement.
8. Membrane Cleaning: Prepare cleaning solution. Circulate through membrane. Rinse thoroughly. Test water quality after cleaning. Replace if performance declines.
9. System Winterization: Drain water if freezing is possible. Disconnect power. Remove and store filters. Protect against frost damage.
10. Performance Optimization: Adjust pressure settings. Clean pre-filters regularly. Avoid extreme temperatures. Use system daily for best results.
Q: How often should I replace the RO membrane in the system?
A: The RO membrane typically lasts 2-3 years, depending on water quality and usage. Regular monitoring and periodic replacement ensure optimal performance.
Q: Can the system remove bacteria and viruses from the water?
A: Yes, our reverse osmosis system effectively removes bacteria, viruses, and other microorganisms, providing safe and purified water.
Q: Is it necessary to install a pre-filter before the RO system?
A: Yes, a pre-filter is recommended to remove larger particles and sediment, prolonging the lifespan of the RO membrane and enhancing overall system performance.
Q: Can the system be used with well water?
A: Yes, our system is suitable for well water. However, additional pre-treatment may be required based on the specific water quality and contaminants present.
Q: How long does it take to produce purified water?
A: The production time varies depending on factors such as water pressure and system capacity. On average, our system produces 1-2 gallons of purified water per minute.
Product Advantage:
1. High Capacity: Our system boasts a 5000L RO capacity, ensuring a continuous supply of purified water for industrial production needs.
2. Superior Water Quality: With reverse osmosis technology, our system effectively removes impurities, contaminants, and harmful substances, providing high-quality water for industrial applications.
3. Cost-effective Solution: By eliminating the need for expensive bottled water or alternative purification methods, our system offers a cost-effective solution for industrial water filtration.
4. Easy Maintenance: Our system is designed for easy maintenance, with accessible filters and user-friendly controls, minimizing downtime and maximizing productivity.
5. Reliable and Durable: Built with high-quality materials and advanced technology, our Water Filtration System Reverse Osmosis ensures long-lasting performance and reliability in industrial environments
model | Water yield | Electric power | Recovery | Primary effluent conductivity us/cm | Secondary effluent conductivity us/cm | EDI effluent conductivity us/cm | Raw water conductivity |
RO500 | 0.5 | 0.75 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO1000 | 1.0 | 2.2 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO2000 | 2.0 | 4.0 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO3000 | 3.0 | 5.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO5000 | 5.0 | 7.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO6000 | 6.0 | 7.5 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO10000 | 10.0 | 11 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
RO20000 | 20.0 | 15 | 55-75 | ≤10 | 2-3 | ≤0.5 | ≤300 |
1. Beverage Production: Our system provides purified water for beverage production, ensuring the highest quality and taste for soft drinks, juices, and bottled water.
2. Pharmaceutical Manufacturing: The system is ideal for pharmaceutical companies, delivering purified water that meets the stringent requirements of drug manufacturing processes.
3. Electronics Industry: Our system supplies ultra-pure water for electronics manufacturing, preventing contaminants that could damage sensitive components and ensuring product reliability.
4. Food Processing: The system is used in food processing plants to remove impurities and contaminants, ensuring safe and clean water for various production processes.
5. Power Generation: Our system is employed in power plants, providing purified water for boiler feedwater, cooling towers, and other critical applications, ensuring efficient and reliable power generation.
1. Pre-Installation Check: Verify all components. Review installation manual. Ensure tools are available. Check for shipping damage.
2. System Connection: Connect to water source. Install plumbing fittings. Attach drain line. Connect storage tank. Follow connection guidelines.
3. System Start-up: Open water supply valve. Allow system to fill. Check for leaks. Flush system. Test initial water output.
4. Regular Maintenance: Replace filters on schedule. Clean membrane annually. Sanitize storage tank. Check system pressure. Monitor water quality.
5. Troubleshooting: Consult manual for common issues. Check water pressure and flow. Inspect for leaks. Test water quality. Contact support if needed.
6. Water Quality Testing: Use provided test kit regularly. Compare results to standards. Adjust system if necessary. Document test results.
7. Filter Replacement: Turn off water supply. Release system pressure. Remove old filters. Install new filters. Sanitize system after replacement.
8. Membrane Cleaning: Prepare cleaning solution. Circulate through membrane. Rinse thoroughly. Test water quality after cleaning. Replace if performance declines.
9. System Winterization: Drain water if freezing is possible. Disconnect power. Remove and store filters. Protect against frost damage.
10. Performance Optimization: Adjust pressure settings. Clean pre-filters regularly. Avoid extreme temperatures. Use system daily for best results.
Q: How often should I replace the RO membrane in the system?
A: The RO membrane typically lasts 2-3 years, depending on water quality and usage. Regular monitoring and periodic replacement ensure optimal performance.
Q: Can the system remove bacteria and viruses from the water?
A: Yes, our reverse osmosis system effectively removes bacteria, viruses, and other microorganisms, providing safe and purified water.
Q: Is it necessary to install a pre-filter before the RO system?
A: Yes, a pre-filter is recommended to remove larger particles and sediment, prolonging the lifespan of the RO membrane and enhancing overall system performance.
Q: Can the system be used with well water?
A: Yes, our system is suitable for well water. However, additional pre-treatment may be required based on the specific water quality and contaminants present.
Q: How long does it take to produce purified water?
A: The production time varies depending on factors such as water pressure and system capacity. On average, our system produces 1-2 gallons of purified water per minute.
We have always been committed to maximizing the "Wejing Intelligent" brand - pursuing champion quality and achieving harmonious and win-win results.